Here you go:
WARNING: During this procedure, all user stored data will be deleted. If the
current settings and data are not expendable, create a backup before executing the Factory Reset. Backup Reference:
MIDI Bulk Dump OM Pgs. 143-144 The following data will be deleted: Automix Memory, Scene Memory, EQ Libraries (user only), Dynamics Libraries (user only)
Channel Libraries (user only), Effects Libraries (user only) and all other user
system settings.
The 02R has an internal lithium (CR2032) backup battery that will need to be changed periodically. The status of the battery can be checked in UTILITY
page 4. The battery only needs to be changed if the status message indicates '
VOLTAGE LOW'. It does not need to be changed if the status message indicates 'OKAY'.
Turn the 02R off. Do not attempt to replace the battery with the 02R on.
Remove the 10 ten screws from the panel on the back of the 02R that has the Wordclock, Time Code Input,
AES/
EBU, and
MIDI connections.
Carefully pull the panel out.
The battery will be on the left
hand side, as you
face the rear of the 02R. Remove the battery and replace it.
The 02R will now need to be reinitialized.
Press and hold down the left cursor
button while turning the
power on.
Continue to hold the buttons down until a dialog box appears on the display which reads:
PLEASE CONFIRM
Initialize memory
[ ] Cancel [ ] Execute
Using the cursor buttons, navigate to the ''EXECUTE option and press [ENTER].