Hi Everyone,

I would really like to upgrade our high school auditorium CD80SV rack with a newer C21 retrofit processor. This would give us Vision.net capabilities. Our Outlook panels and wall switches for house lights are a pain. Very glitchy, and very much in need of replacement. Does anyone know if the vision.net panels require a complete rewiring, or would they be able to use the existing Outlook wiring within the system?

Thanks!
 
Hi Everyone,

I would really like to upgrade our high school auditorium CD80SV rack with a newer C21 retrofit processor. This would give us Vision.net capabilities. Our Outlook panels and wall switches for house lights are a pain. Very glitchy, and very much in need of replacement. Does anyone know if the vision.net panels require a complete rewiring, or would they be able to use the existing Outlook wiring within the system?

Thanks!
@mr10r @Ron Foley Would you mind answering this poster's queries??
Toodleoo!
Ron Hebbard
 
the existing control wire Belden 9773 for Outlook work just fine for Vision net
We are now well over (50 -60 ) C 21 retrofits , that we have also replaced the Outlook for Visionnet

Vision net is very robust
the C21 retrofit kits have been rock solid.

We have even replace Accent control stations that only used straight up #18 AWG wire
(no shield) no pairing no twisting.


we make adapter plates for the refit, the new slider stations do not use and many gangs as Outlook.

let me know if you need further information

[email protected]
 