Recent content by Control point

  1. C

    Control/Dimming Sensor Relay Cards

    Drd racks use R20- part 7083A1085 Sensor racks use R20AF -part 7050A1085 Both the same list price. Remember to park them on your console .
  2. C

    Light in eyes bothering performers

    If you can have her walk the blocking cue to cue and ask her to identify it - if she does hit on a couple fixtures irritating her, you might try adding a cut of Hamburg frost to the gel in the fixture- if it doesn’t ruin your field too much. A tiny bit of frost can take the edge off an...
  3. C

    Over-Lamping Dimmer Packs

    No. Period. Especially if you don’t own the gear - and dont carry enough insurance. Go borrow 575 or smaller lights . No. Period.
  4. C

    LED retrofit

    We had a client use an led tape that worked out very cheap, a bit of work making each one up but they loved it- I think the company was green life ? They cut the LED tape- soldered on little 18 gauge wires and tied into the 12 bolt. Carmel
  5. C

    Strategy for upgrading theater lighting

    I think reading the Seattle paper is really helpful in terms of perspective of why to use LED’s- boiled down it’s not energy savings ( except on a cyc ) it’s for color . You have a good base in the strand rack - because it has relay modules available for you to start distributing power for...
  6. C

    Control/Dimming Older System (1969)

    Dawn, you are looking at the patch panel portion of the system - this inter connects the circuits ( track lights ) to the dimmers. If you had a licensed electrician carefully remove thi s panel you would probably see six bolt in dimmers behind it. They usually analog dimmers, that get...
  7. C

    Control/Dimming L21-30 for portable dimmer power

    If you are powering LED’s - try an ETC Colorsource relay - wired or wireless. Nice clean way to manage the data and power. Don’t use dimmers to power LED’s. Good rule of thumb.
  8. C

    Control/Dimming Pulses and flickers in High School Theatre lighting

    I might suggest two things - 1- clean the racks and filters.. could be an airflow issue. 2- our of curiosity, have they added moving lights or LED’s to their rig ? If so.. how are they getting DMX to those devices, and how are they managing the power to them.I see a lot of schools buying...
  9. C

    Why pipes and not unistruts?

    Electro controls- sent from “ an old gal “
  10. C

    Control/Dimming LED Par malfunction

    Aedan, First, everyone is correct, find and use a constant A/C source or invest in a relay module at the dimmer rack. The mistake you are making by setting a dimmer circuit to non - dim profile is common as venues are buying LED’s and movers and not taking care of how to get power to them. I...