Recent content by Eugene Palmer

  1. E

    I broke my Rosco Delta 3000, Help!

    Point taken. In fact I think I ruined the heater as it doesn't respond at all after its first test. Oh well, its off to the recycling dump. I guess that pair of 25amp SCR's was there for a reason.
  2. E

    I broke my Rosco Delta 3000, Help!

    I also have a broken Delta 3000, which is no longer supported by Rosco, no parts, nada. I didn't plug network POE to it but someone else may have. However, I have it working in Caveman Mode, which means that since the heater is good and the pump is good you can remove the electronics entirely...