Control/Dimming Gantom DMX Fixture Termination?

icewolf08

CBMod
CB Mods
Hey friends, does anyone know if the Gantom DMX fixtures (specifically the GT22) have DMX termination or not? This could significantly affect the topology of a system I am setting up with them.
 
Fastest answer is with a meter! Measure between pins 2 and 3. ~120 ohms = yes, High z = no
 
It's only fast if you already have the gear. If you're trying to decide what to buy then it's not really an option.
 
Well, to follow up: The response i got from Gantom is that they do terminate the chain. However, they way they phrased their messge to me makes me wonder if they didn't really understand what I meant by termination (which would be problematic). Their message text below:

Gantom Lighting said:
The GT22 does not have a DMX Thru port, only a DMX Input. This means it would serve to terminate the DMX signal with no additional terminator necessary.

The problem I have with this statement is that they sell a DMX Y-adapter (which is problematic in and of itself) to plug in multiple fixtures, which, if each fixture has termination would add multiple terminators to a chain. All of this seems a little off.
 

Users who are viewing this thread