Recent content by kwhite177

  1. K

    Capture Argo Connectivity Troubleshooting

    The Pearl is sending DMX to the artnet converter. Cat5 out of the converter to the router.
  2. K

    Capture Argo Connectivity Troubleshooting

    Apologies if this has been covered in a different thread.I cannot get my console to talk to my PC running Capture Argo for pre visualization and programming.I am very new to artnet so I have a feeling my issue is within the ip addressing. I was not apart of the artnet node purchase so I am...
  3. K

    Automated Fixtures ROBE Robin DLX

    Hello all,I work for a small Audio Video and Lighting company who is in the process of upgrading from our cheaply made, problem ridden moving fixtures. My boss is suggesting to purchase some ROBE Robin DLX fixtures. Since I have never used these fixtures let alone ROBE fixtures at all, I can...
  4. K

    Automated Fixtures Uncontrollable Mover

    Thank you! This will definitely help me make sure I havent missed any steps. I have had to put this project aside because of the busy holiday season but as soon as I have the time I will definitely use this flowchart!
  5. K

    Automated Fixtures Uncontrollable Mover

    All dmx and power cables have been fully tested. I have been the only one to do any sort of cleaning or repairs on the unit for the last 6 months and have had the unit in question working before. The only repair this mover has had in that time period is a replaced ballast. I checked the input...
  6. K

    Automated Fixtures Uncontrollable Mover

    swapped both pcb's and still nothing.
  7. K

    Automated Fixtures Uncontrollable Mover

    "#2" works fine on the same adress receiving DMX from "uncontrollable." I have checked continuity to from the DMX to the main board and it is fine. There are two pcb's after the main board. I will try swapping those out with working boards from another fixture.
  8. K

    Automated Fixtures Uncontrollable Mover

    yes I have checked the patching and addresses multiple times, and changed addresses multiple times as well.The second fixture that was receiving DMX from the fixture in question works on both the same DMX address and a separate address all together.
  9. K

    Automated Fixtures Uncontrollable Mover

    Hi, I'm an up and coming LD having some issues with a mover. I was hoping someone could give me some advice on the next step I should take.The fixture in question is a Deliya Vision 575 Spot. (I know they're not the best fixtures...but it's what I have) When I turn it on everything works...