Recent content by turtle7896

  1. turtle7896

    Colortran ENR24

    What still baffles me is why all of the house lights aren't on a whole separate 24 dimmer rack. Are house lights are patched in our first universe (because there really only is one with this system) with addresses 40-59. 40-48 are in the rack back stage, and 49-58 or 59 are on that smaller rack...
  2. turtle7896

    Colortran ENR24

    It's been a while, but this just makes me gawk at my school. This has to be one of the dumbest and most inefficient designs I have seen and heard about with dimmer racks. There are the main 48 in the one picture, and then the other 10 for the rest of our house lights. I also makes me wonder why...
  3. turtle7896

    Router for ETC Element

    Sorry I had forgotten about this. Appreciate all the responses, we found a small linksys router that has been working great.
  4. turtle7896

    Router for ETC Element

    Hey everyone. Just need any recommendations for a router to use for an ETC Element. My school is investing in the aRFR app, but we need a solid router to get the job done. Let me know if you would need any other information and thank you in advance!
  5. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Unfortunately since I also attend a private school with absolutely no tax money, they divert all alumni or other money to sports, e-sports, and what ever else is "needed" because nobody really gives a crap about our auditorium besides me and like 2 others students. One of our eplisodals started...
  6. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Gonna be entirely honest because I don't think I have fully explained it. I'm literally a high-schooler in a significantly underfunded, under-supported, and understaffed stage crew. Half the time I have no clue what I am talking about, and somehow I know more than our IT person, which is the...
  7. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Alright. So, based on what @STEVETERRY has said, among everyone else, what is my best way to approach all of this? We need to change out 4 separate dimmers due to very, very inefficient power and horrible wiring done 30 years ago.
  8. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    https://www.controlbooth.com/threads/colortran-enr24.48926/
  9. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Thanks for all of the ideas and the help fellas. I might go with mircostar's idea of having the dimmers converted to a non-dim, but if it would be more ergonomic to run a piece of conduit up the wall, and then take an Edison - power-con right into it, we may do that. We also need to deal with...
  10. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Here is what we are working with. There is another panel in the basement, but as it may be evident, we would probably not be able to work with it.
  11. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Haha, thanks again man.
  12. turtle7896

    Walkie-talkies

    Sorry for the long delay. Thanks for the ideas. We just pulled some new wiring up through the ceiling so everything will be operational soon.
  13. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Alright, thank you. I'll shoot Steve an email.
  14. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    One last thing, are constant modules the same as relays/non-dim?
  15. turtle7896

    Attaching a 50', 14 AWG extension cord to a wall

    Is there a website or email I can use to contact him?