Recent content by Titanium

  1. T

    ColorTran ColorNet

    In addition, if ran the colrnet to a NPC or DHV and wired the dmx out of the NPC or DHV to your rack you could then use colornet to transfer your DMX data to the NPC or DHV outputs via ethernet.
  2. T

    Lee/Colortran SceneMaster 60 Manual

    I have uploaded the manual to this post.
  3. T

    Dimmer Protocol

    Leviton makes a protocol converter made for DMX in to CMX out. OPT-00501-2 (DMX/MPX to CMX).
  4. T

    nsi ncm 7232 question

    I have excellent luck with him too. HAHA
  5. T

    CMX-DMX Protocol

    Leviton IF501-1 will convert CMX to DMX.
  6. T

    leviton innovator

    Please contact Leviton Tech Support @ [email protected] or 800-959-6004.
  7. T

    Fast console but slow dimmers

    If your still out there. What model Colrtran Dimmer?
  8. T

    NSI/Leviton Controllers

    Hi! Patterns for page 2 start at pattern number 25, page 3 patter 49, and page 4 at pattern 73. Let us know if any other questions arise.
  9. T

    Control/Dimming Leviton D4DMX and ETC console

    I would suggest trying to adjust the amount of channels in the DMX packet, if you are not sending all 512 channels, try increasing to 512. If the pack is within the two year warranty period, we could arrange for it to be evaluated by our repair department. Leviton Technical Support can be...
  10. T

    NSI/Leviton Controllers

    For Closure for everyone: Looks like the console was taking its time to go into group edit mode. Please feel free to contact us if you have any questions or concerns.
  11. T

    NSI/Leviton Controllers

    That is the way to tell the controller which fixtures are to be in each group. There is no other way to group the fixtures. What fixtures are you using? If they are not the same model fixture, do the fixtures have any traits in common. IE GOBO, COLOR, DIMMER, ECT... Please email me at...
  12. T

    NSI/Leviton Controllers

    Are you referring to the following menu... [EDIT] [SETUP] [FIXTURE] [GROUP] ??
  13. T

    NSI/Leviton Controllers

    The version can be located by watching the screen after the units power is turned on. Latest version is 2.08.09 Sorry for the confustion, yes the console can retain the "shows" on the console, i was referring to backing up the whole console file as a show. The same manual applies for both...
  14. T

    Leviton LumaNet Keypads

    The 4006 is the remote dimmer that needs to be controled from a D4200 or D4206 unit. The scene controllers will not work with just a D4006, you need a D4200 or D4206 to setup scenes. Please let us know if you have any other questions or concerns by contact us (leviton) at 800-959-6004 or...
  15. T

    Control/Dimming NSI MC 24/48

    Do you have two video outputs? This symptom can show up if the second video card fails. If you do have a second video card installed, please remove and try doing factory default again. Otherwise, we would recommend you contact us at 800-959-6004 or [email protected] to have the unit...
Back